Water and Sewer Design & Construction Standards

Donation standard specifications are regularly updated and made available.

  • Preface and Organization
  • Part I - Donation Utility Construction
  • Part II - General Provisions
  • Part III - General Material & Methods of Construction
  • Part IV - Miami-Dade Water and Sewer Department Standard Details
  • Part V - Appendices 

All the files below are presented in  PDF format, or  DWG format where noted.

Part I - Donation Utility Construction
Donation Water Mains
Section Number
Section
Title
Current
Issue Date
33 14 13 (UC-000) Water Mains 10-2019
33 05 31.16 PVC C900 Water Main 04-2023
UC-005

Project Approval

2-2015
UC-033 Concrete, Mortar and Grout (Short) 6-2005
UC-055 Structural Work 8-1999
UC-075 Water Service Installations 7-2013
UC-080 Meter Boxes, Sectional Plates and Vaults for Water Service 1-1999
UC-085 Water Meter Valves 1-1999
UC-090 Piling for Aerial Crossing 8-1999
UC-170 Cleaning and Testing Mains 2-2011
UC-175 Disinfection of Mains 1-1999
Donation Wastewater Gravity Systems
UC-250 Gravity Sewer Systems 8-2011
UC-290 Removal of Sanitary Sewerage and Debris 1-1999
UC-300 Gravity Sewer Pipe Foundation 1-1999
UC-310 Gravity Sewer Service Laterals 8-1999
UC-320 Sewerage Bypass Pumping and Flow Control 6-2005
UC-330 Repairs to Department Sewers 8-1999
UC-350 Sewer Deflection Test 1-1999
UC-370 Cleaning and Testing Gravity Sewers 2-2011
Donation Pumping Stations
02540 Pump Station 10-2017
16051 Pump Station Electrical Materials 10-2017
16940 Pump Station Control Panel 10-2017
02534 Pump Station Testing 10-2017
Donation Force Mains
UC-750 Donation Force Mains 11-2010

33 05 31.13 

(15068)

PVC C900 Sewer Force Main 03-2021
Reclaimed Water Systems
UC-800 Reclaimed Water System Design and Construction Specifications 6-2008



ˆ top

Part II - General Provisions
Division 1 - General Requirements
Section Number
Section
Title
Current
Issue Date
01005 Defined Terms 5-2017
01010 Summar of Work 5-2017
01011 Site Conditions   5-2017
01016 Safety Requirements and Protection of Property 5-2017
01018 Environmental Contamination 5-2017
01031 Grades, Lines and Levels 5-2017
01070 Cutting and Patching 5-2017
01090 Reference Standards 5-2017
01100 Special Project Procedures 5-2017
01140 Security 5-2017
01150 Preconstruction Conference 1-1999
01340 Shop Drawings 5-2017
01380 Construction Photographs and Video Photography 5-2017
01410 Testing and Testing Laboratory Services 5-2017
01581 Project Signs 5-2017
01600 Materials and Equipment Shipping, Handling, Storage and Protection 5-2017
01700 Contract Closeout 5-2017
01710 Cleaning 5-2017
 01720 Project Record Documents  9-2016
01 78 40 (01725) Project As-Built/Record Drawings 12-2020
01730 Operating and Maintenance Data 1-1999
01740 Permits 5-2017
01750 Maintenance of Traffic and Public Streets 5-2017



ˆ top

Part III - General Material & Methods of Construction

Division 2 - Site Work

Section Number
Section
Title
Current
Issue Date
02230 Clearing and Grubbing 8-1999
02260 Steel Sheet Piling 1-1999
02314 Excavation, Backfill and Fill for Structural
Facility and Utility System
8-1999
02315 Trenching and Backfilling for Piping Systems 8-1999
02505

Cleaning and Testing of Main

Effective July 1, 2016 Potable Water Mains shall be tested at 150 psi per Health Department Requirements

5-2016
02536 Precast Manholes & Covers 9-2016
02615 Concrete Protective Liner System for Precast Structures 8-1999
02625 Sanitary Sewer Manhole Infiltration Insert 3-2011
02741 Prime and Tack Coats 1-1999
02745 Pavement Removal and Replacement 1-2019
02765 Pavement Markings and Traffic Signs 1-1999
02822 Chain Link Fences and Gates 2-2009
02900 Landscaping 5-2010

Division 3 - Concrete

03300 Cast-in-place Concrete, Reinforcing and
Formwork
5-2009
03375 Flowable Fill 5-2011
03400 Precast Prestressed Concrete 1-1999
03520 Lightweight Concrete 2-2017
03600 Grout 2-2017

Division 4 - Masonry

04060 Mortar 1-1999
04082 Joint Reinforcement 1-1999
04220 Unit Masonry 1-1999

Division 5 - Metals

05120 Miscellaneous and Structural Steel 1-1999
05140 Structural Aluminum 1-1999
05520 Aluminum Railings 1-1999
05540 Access Hatches 8-1999
05550 Castings 6-2015

Division 6 - Wood and Plastics

  (Not Used)  

Division 7 - Thermal and Moisture Protection

07550 Built-Up Bituminous Roofing 2-2017
07620 Sheet Metal Flashing and Trim 2-2017
07920 Sealants and Caulking 2-2017
07222 Rigid Tapered Roof Board Insulation 2-2017

Division 8 - Door and Windows

08110 Steel Doors and Frames 6-2005
08710 Finish Hardware 1-1999
08720 Aluminum Louvers 6-2005

Division 9 - Finishes

09801 Concrete Protecting Coatings 1-1999
09900 Painting (Short) 7-2012

Division 10 - Specialties

  (Not Used)  

Division 11 - Equipment

11205 Submersible Wastewater Pumps 5-2023
11210 Vertical (Dry-Pit) Centrifugal Sewage Pumps 9-2016
11215 Sump Pump 8-1999
11500 Fuel Storage Tanks 8-2013

Division 12 through 13

  (Not Used)  

Division 14 - Conveying System

14050 Crane, Trolley and Hoist 1-1999
14060 Hoist and Trolley 1-1999

Division 15 - Mechanical

15010 Basic Mechanical Requirements 1-1999
15040 Seal Water System 8-1999
15060

Piping and Fittings
Effective 11-04-2016 Ductile Iron mains in salt water areas shall have a zinc coating and encasement in V Bio Polyethlene

11-2016
15065 Miscellaneous Materials 8-2011
15070 Jacking and Boring 1-1999
15075 Aerial Crossing 8-1999
15080 Horizontal Directional Drilling 1-1999
15100 Valves, General 9-2015
15102 Tapping Sleeves and Tapping Valves 7-2024
15110 Butterfly Valves 8-1999
15115 Check Valves 1-1999
15120 Gate Valves 11-2015
15125 Plug Valves 9-2017
15130 Miscellaneous Valves 1-2019
15330 Fire Hydrants 12-2006
15821 Dehumidifier 1-1999
15860 Air Moving Equipment 12-2009

Division 16 - Electrical

16152 Variable Frequency Drives 12-2009
16420 Stationary Standby Engine/Generator Set 6-2005
16425 Portable Engine-Generator Sets 12-2006
16780 S. C. A. D. A. System R. T. U. Installation 12-2006
26 05
73.19
Short-Circuit/Coordination Study/Arc Flash Hazard Analysis 12-2021
     
  Other Divisions  
350000  Commercial Diver Specification 07-2023



ˆ top

Part IV - MDWASD Standard Details
General Details
Detail Number
Description
Sheet Number
Current Issue date
GS 0.5 Standard Requirements for Water and Sewer Construction 1 of 2 7/20/2016
GS 0.5 Record Drawing Requirements 2 of 2 7/20/2016
GS 1.0 Typical Tie-Rod Details 1 of 1 7/20/2016
GS 1.1 Potable Water Main / Force Main Pressure Pipe Conflict Detail 1 of 1 7/20/2016
GS 1.2 Reinforced Concrete Slab (For Ground Cover less than 2.5') 1 of 1 7/20/2016
GS 1.3 Buttweld for Field Welding 1 of 1 7/20/2016
GS 1.4 Pipe Guard (12" Pipe and Larger) and Pipe Guard Bolt Detail) 1 of 2 7/20/2016
GS 1.4 Typical Aerial Canal Crossing (Single Piles) 2 of 2 7/20/2016
GS 1.5 Potable Water Main. Wastewater & Storm Sewer Conflict 1 of 2 10/1/2017
GS 1.5 Water and Sewer Main Crossings 2 of 2 10/1/2017
GS 1.6 Flanged Outlet For Access 1 of 1 7/20/2016
GS 1.7 Typical Tapping Valve Setting (16" and Smaller) 1 of 1 7/20/2016
GS 1.8 Tapping Sleeve and Valve Installation 1 of 1 7/20/2016
GS 1.9 Typical Trench Backfill for D.I. Water and Force Mains 1 of 2 9/22/2022
GS 1.9 Detail for PVC Water and Force Main 2 of 2 9/22/2022
GS 2.0 Standard Requirements for Water & Sewer Mechanical Thrust Restraint 1 of 1 7/20/2016
GS 2.1 Embankment Typical Section 1 of 1 7/20/2016
GS 3.0 Standard Symbols 1 of 2 7/20/2016
GS 3.0 Standard Symbols 2 of 2 7/20/2016
GS 4.0 Sign Details 1 of 2 7/20/2016
GS 4.0 Sign Post Installation 2 of 2 7/20/2016
GS 5.0 Casing Installation 1 of 2 9/26/2017
GS 5.0 Casing Installation 2 of 2 9/26/2017
Water Detail
WS 1.0 Typical Gate Valve Setting (Smaller than 16") 1 of 1 10/10/2008
WS 1.60 Air Release Valve 1 of 1 06/9/2016
WS 1.61 Typical Flushing Valve Outlet 1 of 1 10/1/2017
Water Box and Vault Details
WS 2.05 Casting Standards 1 of 1 6/1/2015
WS 2.10 Single Meter Box Installation 1 of 3 6/1/2008
WS 2.10 Single Meter Box Detail 2 of 3 6/1/2008
WS 2.10 Single Meter Box for Multi-Story Building 3 of 3 6/1/2008
WS 2.12 Dual Meter Box 1 of 2 11/1/2006
WS 2.12 Dual Meter Box Installation for two 5/8" Meters 2 of 2 10/29/2010
WS 2.16 Typical 2" Service Installation with a 2" meter 1 of 4 5/31/2013
WS 2.16 Typical 2" Service Installation with a 1-1/2" meter 2 of 4 5/31/2013
WS 2.16 Typical 1" Service Connections (Copper or HDPE) 3 of 4 1/3/2011
WS 2.16 Typical 2" Service Connections (HDPE) 4 of 4 12/16/2009
WS 2.17 Assembled 2' x 4' Vault (Precast Sections) 1 of 5 11/1/2006
WS 2.17 Assembled 2' x 4' Vault (Precast Sections) 2 of 5 11/1/2006
WS 2.17 Standard 2' x 4' Steel Cover Plate for Non-Traffic Vault 3 of 5 11/1/2006
WS 2.17 Details of 2' x 4' Steel Cover Plate for Non-Traffic Vault 4 of 5 11/1/2006
WS 2.17 2' x 4' Precast Meter Vault for Non-Traffic Areas 5 of 5 11/1/2006
WS 2.19 Standard Precast Meter Vault for Traffic Areas 1 of 1 6/1/2008
WS 2.20 4' x 4' Precast Sectional Meter Vaults for Non-Traffic Areas 1 of 2 11/1/2006
WS 2.20 4' x 4' Precast Meter Vault for Non-Traffic Areas 2 of 2 11/1/2006
WS 2.21 Easement Requirements for Service & Fire Hydrants 1 of 3 10/5/2009
WS 2.21 Easement Requirements for 8" Turbine Meter 2 of 3 11/1/2006
WS 2.21 Easement Requirements for 10" Turbine Meter 3 of 3 11/1/2006
WS 2.30 8-Inch Blow-Off Detail for a 20” D.I. Distribution Main 1 of 1 6/20/2008
WS 2.40 Typical Installations for Medical Facilities or Any Other Facilities Req. by WASD 1 of 1 11/1/2006
Water Piping Details
WS 3.10 No. 2 C.I. Valve Box and Lid 1 of 1 6/1/2008
WS 3.11 No. 3 C.I. Valve Box 1 of 2 6/1/2015
WS 3.11 No. 3 C.I. Lid 2 of 2 6/1/2008
WS 3.12 Typical M.J. Butterfly Valve (24" and Smaller) 1 of 1 10/10/2008
WS 3.13 Leak Detector/Sampling Port Assembly Detail 1 of 1 6/1/2008
WS 3.14 Manhole for Butterfly Valve (30" and Larger) 1 of 3 11/1/2006
WS 3.14 Manhole for Butterfly Valve (30" and Larger) 2 of 3 11/1/2006
WS 3.14 Manhole for Butterfly Valve (30" and Larger) 3 of 3 11/1/2006
WS 3.15 Steel Cover Assembly for No. 66-S Concrete Meter Box 1 of 2 11/1/2006
WS 3.15 Standard 34"x34" Steel Cover Plate for Non-traffic Areas Only 2 of 2 11/1/2006
WS 4.10 Typical Service Plan 1 of 1 11/1/2006
WS 4.12 Typical Connection to Existing Main 1 of 2 6/20/2008
WS 4.12 Typical Connection to Existing Main 2 of 2 6/20/2008
WS 4.13 Typical 2" Galvanized Steel Connection to Existing Main 1 of 1 6/22/2009
WS 4.16 Meter Bank – 2” Supply 1 of 2 11/1/2006
WS 4.16 Meter Bank – 4” Supply 2 of 2 6/1/2008
WS 4.18 Reduced Pressure Zone Backflow Preventer for Water Service 3/4" thru 2" 1 of 3 3/22/2022
WS 4.18 Reduced Pressure Zone Backflow Preventer for Water Service 4" thru 8" 2 of 3 3/22/2022
WS 4.18 Reduced Pressure Zone Backflow Preventer for Water Service - Notes 3 of 3  3/22/2022
WS 4.19 Pressure Vacuum Breaker, Irrigation System Only 1 of 2 11/1/2006
WS 4.19 Pressure Vacuum Breaker, Irrigation System - Notes 2 of 2 11/1/2006
WS 4.20 Typical Fire and Fire & Domestic Water Service Connections 1 of 4 10/5/2009
WS 4.20 Double Detector Check Valve Assembly for Fire Line Service 2 of 4 9/30/2009
WS 4.20 Double Detector Check Valve Assembly for Fire Line Service - Notes 3 of 4 9/30/2009
WS 4.20 Double Detector Check Valve in Parallel 4 of 4 9/30/2009
WS 4.21 Typical Pipe Layout for 4" Service 1 of 2 10/5/2009
WS 4.21 Typical Pipe Layout for Domestic and Irrigation Service 2 of 2 9/16/2008
WS 4.50 Typical Fire Hydrant Installation with Guard Posts 1 of 2 2/25/2013
WS 4.50 Typical Fire Hydrant Installation in FDOT Right-of-Way 2 of 2 2/25/2013
WS 4.60 Water Main Crossing Drainage Ditch 1 of 1 6/1/2008
WS 4.70 R.S. Gate Valve Flushing Port Connection in Horizontal Position 1 of 1 10/9/2015
Reclaimed Water Details
RGN 1.0 Reclaimed Water Mains, General Notes 1 of 2 6/1/2008
RGN 1.0 Reclaimed Water Mains, General Notes 2 of 2 6/1/2008
R 1.0 Sign Post Installation 1 of 1 6/1/2008
R 2.0 Typical Residential Utility Layout Single Service Connections 1 of 1 6/1/2008
R 3.0 Residential Service Connection 1 of 1 6/1/2008
R 4.0 Pipe Identification 1 of 1 12/16/2010
R 5.0 Locating Devices for Non-Metallic Pipe 1 of 1 6/1/2008
Sewer Details
SS 1.0 Gravity Sewer Service Lateral for "Shallow" Sewers 1 of 2 8/26/2010
SS 1.0 Gravity Sewer Service Lateral for "Deep" Sewers 2 of 2 8/26/2010
SS 3.1 Wye Branch Connection for Existing Shallow Main 1 of 1 11/17/2009
SS 3.2 Saddle Tee Fastened to Gravity Sewer Main Liner 1 of 1 2/11/2009
SS 4.0 Type "A" Manhole Cover and Frame 1 of 2 6/1/2015
SS 4.0 Type "A" Manhole Cover and Frame 2 of 2 6/1/2015
SS 5.0 Sewer Main or Lateral thru Drainage Ditch 1 of 1 11/1/2006
SS 6.0 Standard Manhole  1 of 3 9/30/2014
SS 6.0 Standard Manhole  2 of 3 9/30/2014
SS 6.0 Standard Manhole  3 of 3 9/30/2014
SS 6.1 Standard Manhole, Flow Channels 1 of 1 4/13/2009
SS 6.2 New Connection to Existing Manhole (Where no Stub-Out Exists) 1 of 1 11/1/2006
SS 7.0 Shallow Manhole 1 of 1 9/30/2014
SS 8.0 Detail Manhole Adjustment 1 of 1 6/1/2008
SS 9.0 Drop Connection - New Precast Manhole 1 of 1 10/19/2012
SS 10.0 Flow Patterns for Invert Channels 1 of 1 11/1/2006
SS 11.0 Air Release Valve Assembly - Sewage Force Mains 1 of 2 1/22/2019
SS 11.0 Automatic Air Release Valve Assembly 2 of 2 1/22/2019
SS 13.0 No. 53 C.I. Valve Box and Lid 1 of 1 11/1/2006
SS 15.0 Check Valve Manhole 1 of 1 10/6/2009
SS 16.0 6" Plug Valve and Check Valve Manhole 1 of 1 11/1/2006
SS 17.0 Force Main Connection Private Ownership 1 of 1 11/1/2006
SS 18.0 Typical Trench Construction for V.C. and D.I. Pipe Gravity Sewer 1 of 3 11/1/2006
SS 18.0 Typical Trench Construction - PVC Pipe Gravity Sewers in Stable Soils 2 of 3 11/1/2006
SS 18.0 Typical Trench Construction - PVC Pipe Gravity Sewers in Unstable Soils 3 of 3 11/1/2006
SS 19.1 Typical Plug Valve Installation 1 of 1 1/14/2010
SS 21.0 Manhole/Valve Box in Grass Areas 1 of 1 6/1/2008
SS 22.0 Sanitary Sewer Clean-Out Lid Detail 1 of 2 1/14/2010
SS 22.0 Concrete Box for Use with Sanitary Sewer Clean-outs 2 of 2 1/14/2010
SS 23.0 Valve Manhole for Plug Valves 1 of 3 10/1/2017
SS 23.0 Valve Manhole for Plug Valves 2 of 3 10/1/2017
SS 23.0 Valve Manhole for Plug Valves in Conflict with Other Utility 3 of 3 10/1/2017
Accessory Details
A 1.0 Pavement Restoration - Type I 1 of 1 10/7/2010
A 1.1 Pavement Restoration - Type V 1 of 1 8/2/2013
A 1.2 Pavement Restoration - Type II (State Road) 1 of 1 8/2/2013
A 2.0 Pavement Restoration - Type III 1 of 1 11/1/2006
A 3.0 Pavement Restoration - Type IV 1 of 1 11/1/2006
A 4.0 Pavement Restoration - Type M 1 of 1 11/1/2006
A 8.0 Support for Carrier Pipe inside Casing 1 of 1 11/21/2011
A 9.0 Polyethylene Encasement for Ductile Iron Pipe 1 of 1 10/29/2010
A 10.0 Abbreviations for Department's Projects 1 of 3 6/1/2008
A 10.0 Abbreviations for Department's Projects 2 of 3 6/1/2008
A 10.0 Abbreviations for Department's Projects 3 of 3 6/1/2008



ˆ top

Part V - Appendices

Appendix A - Pump Station Design Package
Pump Station Design Package (PSDP-4/96) (3 Pages)
Pump Station Technical Plans Review and Approval Transfer Form (PSPR-4/96) (1 Page)

Appendix B - Supplemental Design Guidelines for Lift Stations and Force Mains (66 pages)
(Developed through WASD Pump Station Improvement Program, May 1994, Revised Jan. 1999)

Appendix C - Sewer Pump Station Guidelines (3 Pages)
(Developed by WASD Engineering Division Staff, Revised Jan. 1999)

Appendix D - Basic Guide to Corrosion Protection
(Basic Corrosion Guide 2017)

Appendix E - Standard Pump Station Drawings

 

 Submersible Pump Station With Stand By Generator
Sheet No.
Title
PDF
DWG
Revision Date
C-1 Cover Sheet 06-2015
C-2 Site Plan, Legend and Notes 06-2015
M-1 Mechanical Plan, Sections, Details and Pump Data 06-2015
M-2 Sample-Fuel Storage Tank Plan and Details 06-2015
E-1 Electrical General Notes 12-2021
E-2 Electrical Site Plan and Notes 10-2019
E-3 Electrical One-Line Diagram 12-2021
E-4A Control Wiring Diagram Station Controller 10-2019
E-4B Control Wiring Diagram Multismart Pump Station Manager 10-2019
E-5 Electrical Control Panel and Details 10-2019
E-6 R.T.U. Installation and Wiring Diagrams 10-2019
E-7 Electrical Riser Diagram and Emergency Generator Bld. Floor Plan 10-2019
E-8 Miscellaneous Electrical Details 10-2019
A-1 Emergency Generator Building Floor Plan, Sections and Elevations 06-2015
S-1 Structural General Notes 06-2015
S-2 Wet Well and Vault Valve Structural Plan, Sections and Details 06-2015
S-3 Foundation/Support for Electrical Installations 06-2015
S-4 Chain Link Fence and Gates 06-2015
S-5 Emergency Generator Building Foundation Plan, Roof Plan, Sections and Details 06-2015

 

  Submersible Pump Station Without Stand By Generator
C-1 Cover Sheet 04-2015
C-2 Site Plan, Legend and Notes 04-2015
M-1 Mechanical Plan, Sections, Details and Pump Data 04-2015
E-1 Electrical General Notes 10-2019
E-2 Electrical Site Plan and Notes 10-2019
E-3 Electrical One-Line Diagram 12-2021
E-4A Control Wiring Diagram Station Controller 10-2019
E-4B Control Wiring Diagram Multismart Pump Station Manager 10-2019
E-5 Electrical Control Panel and Details 10-2019
E-6 R.T.U. Installation and Wiring 10-2019
E-7 Electrical Riser Diagram and Details 10-2019
S-1 Structural General Notes 04-2015
S-2 Wet Well and Vault Valve Structural Plan, Sections and Details 04-2015
S-3 Concrete Slab for Equipment 04-2015
S-4 Chain Link Fence and Gates 04-2015

 

 Dry Well/Wet Well Pump Station
Sheet No.
Title
PDF
DWG
C-1 Cover Sheet adobe logo
C-2 Site Plan, Legend and Notes
A-1 Emergency Generator Building, Floor Plan, Sections and Details
S-1 Structural General Notes
S-2 10' x 10' Dry Well w/8' Wet Well Structural Plan, Section and Details
S-3 Ladder Details
S-4 Grating Platform
S-5 Emergency Generator Building Foundation Plan, Floor Plan and Sections
M-1 10' x 10' Dry Well w/8' Wet Well Mechanical Plan, Sections and Pump Data
M-2 Mechanical Details
M-3 Fuel Tank
E-1 Electrical General Notes
E-2 Electrical Site Plan and Notes
E-3 Electrical One-Line Diagram
E4A Control Wiring Diagram Station Controller
E4B Control Wiring Diagram Multismart Pump Station
E-5 Electrical Control Panel and Details
E-6 R.T.U. Installation Wiring Diagram
E-7 Electrical Riser Diagram and Emergency Generator Bldg. Floor Plan

 

Appendix F - Turbine Meter Guidelines

Sheet No.
Title
PDF
DWG
Drawing No.
WM-1 Water Main Turbine Meter Design Guide Plan, Sections and Details

 

 

W-00000-A

 

Appendix G - Sewer Meter Station Guidelines

 Sewer Meter Station
Sheet No.
Title
PDF
DWG
E-1 Sewer Meter Station Design Guide
Electrical Plan and Details
E-2 Sewer Meter Station Design Guide RTU Installation Wiring Diagrams
E-3 Sewer Meter Station Design Guide Electrical General Notes
MS-1 Sewer Meter Station Design Guide Piping, Structural and Details
MS-2 Magmeter with no Venturi Piping, Structural and Details adobe logo AutoCAD logo

Phone Number(s)

Locations and Hours

Water and Sewer

Roy Coley, Director

Water and Sewer Douglas Office
3071 SW 38th Ave, Miami, FL 33146
305-665-7477 | Roy.Coley@miamidade.gov

Contact UsRequest Public Records